Evaporative Cooling Kilmore, Serviced Before Summer Hits

Evaporative Cooling Experts

An evaporative cooler that has sat idle all winter needs a service before the first hot day. Clean pads, a working pump and sealed ducting are what decide whether it cools the house or just moves warm air around.

GET A FREE QUOTE

Dorco Plumbing Contractors

Evaporative Cooling Kilmore: How Ducted Coolers Work

 Commercial Plumbing

Evaporative cooling is one of the most common ways to cool a home in Kilmore and the surrounding Mitchell Shire, because it suits the area's hot, dry summer days and costs little to run. Dorco Plumbing Contractors installs, services and repairs ducted evaporative coolers, with the water connection, drain and electrical isolation done as part of the job.

The roof unit

A fan in the rooftop unit draws hot outside air through filter pads kept wet by a pump that circulates water from the unit's tank. As water evaporates from the pads, the air passing through cools before it is pushed into the house.

Ducts and outlets

Cooled air travels through insulated flexible ducting in the roof space to outlets in the ceilings. Because evaporative cooling relies on a constant flow of fresh air, windows or doors need to be partly open for it to work, unlike refrigerated air conditioning.

Water supply and drainage

The unit is connected to the mains water supply through a float valve, and older water in the tank is drained or bled off so salts and minerals do not build up. A correct water connection and a working drain are plumbing work, which is why a plumber is the right trade to look after the unit.

Bylands Evaporative Cooling
Broadford Evaporative Cooling

Dorco Plumbing Contractors

Pre-Summer Evaporative Cooler Service

 Commercial Plumbing

A yearly service before summer is the single best thing an owner can do for an evaporative cooler.

What a service includes

The service covers cleaning or replacing the filter pads, cleaning the water tank and removing sludge, checking and cleaning the pump and the water distribution system, testing the float valve and the drain or bleed-off valve, inspecting the fan motor and belt, checking the controller, and running the system to confirm airflow at every outlet.

Signs a cooler needs attention

Weak airflow, a musty or stale smell, water leaking through a ceiling outlet, a pump that runs but leaves the pads dry, or a cooler that blows warm air on a hot day all point to a fault that a service will find.

Closing down for winter

At the end of the season the tank is drained and the unit is shut off, and a winter cover is fitted over the roof unit. Kilmore's cold winters make this worth doing, because warm air from the house otherwise escapes up the ducts and the outlets let cold draughts in. Cooler checks can be booked with a general plumbing check; see the plumbing maintenance page.

Dorco Plumbing Contractors

Evaporative Cooler Duct Repair and Airflow Checks

 Commercial Plumbing

The ducting in the roof space is the part of an evaporative cooling system nobody sees, and it is often why some rooms are cool and others are not.

Common duct faults

Flexible ducts can come loose from their fittings, be crushed by stored items or roof work, sag into long loops that slow the air, or split with age. A disconnected duct pours cooled air into the roof space instead of the room, and a torn one can let roof-space dust into the house.

Re-securing and sealing ducts

As part of a service or repair, the ducting is inspected from the roof unit to each outlet. Disconnected runs are re-attached and sealed, crushed sections are re-routed and supported, and damaged lengths are replaced. Airflow is then checked at each outlet so every room gets its share of the cooling.

Bylands Evaporative Cooling
Broadford Evaporative Cooling

Dorco Plumbing Contractors

Evaporative Cooler Pump, Motor and Leak Repairs

 Commercial Plumbing

Many cooler faults are single parts that can be replaced without replacing the unit.

Pumps, float valves and leaks

A failed pump leaves the pads dry, so the cooler blows warm air. A stuck float valve either starves the tank or lets it overflow, and leaks from the tank or connections can stain ceilings below. Each is repaired or replaced and the system re-tested.

Fan motors, belts and controllers

A worn belt or failing motor shows up as noise, slipping or no airflow at all. Controller and wiring faults stop the unit responding. Where the electrical fault is outside the unit, a licensed electrician is involved.

Dorco Plumbing Contractors

Evaporative Cooling Installation and Replacement

 Commercial Plumbing

When a cooler is beyond economical repair, or a home is adding cooling for the first time, a new ducted system is sized to the house. The unit's capacity, the number and position of outlets and the duct layout all depend on the floor area, ceiling heights and how the rooms are used. Replacing an old unit on the same roof position often allows the existing ducting to be reused after inspection, which keeps the cost down. The new unit is connected to water, drainage and power, and commissioned so airflow is balanced across the house.

Bylands Evaporative Cooling
Broadford Evaporative Cooling

Dorco Plumbing Contractors

Evaporative Cooling Versus Refrigerated Air Conditioning

 Commercial Plumbing

Evaporative cooling costs much less to run than refrigerated air conditioning and brings in a constant supply of fresh, filtered air, which many people prefer to recirculated air. It works best on hot, dry days, which suit Kilmore's summers. It is less effective on humid days, needs a water supply, and requires doors or windows to be partly open.

Refrigerated air conditioning cools reliably in any weather and can also heat, but costs more to run and recirculates indoor air. For many homes in the Mitchell Shire, a well-serviced evaporative system covers most of summer at a fraction of the running cost.

Dorco Plumbing Contractors

What Affects the Cost of Evaporative Cooling in Kilmore

 Commercial Plumbing

Cooling work is quoted after the system is inspected. The main factors, from the smallest effect to the largest, are:

  • A standard service. Cleaning, checking and adjusting an otherwise healthy unit.
  • Replacement parts. Pads, a pump or a float valve add to the service.
  • Duct repairs. The number of damaged or disconnected runs and access in the roof space.
  • Major components. A fan motor or controller costs more than a pump or pads.
  • A new system. Installation or replacement is the largest cost, reduced when existing ducts can be reused.
Bylands Evaporative Cooling
Broadford Evaporative Cooling

Dorco Plumbing Contractors

Evaporative Cooling Questions

 Commercial Plumbing

The questions Kilmore homeowners ask most often about evaporative coolers.

How often should an evaporative cooler be serviced?

Once a year, ideally in spring before the first hot spell. Units that run for long periods every summer can need their pads replaced more often.

Why does my evaporative cooler smell?

A musty smell usually means stale water in the tank, dirty or clogged pads, or algae build-up. Draining and cleaning the tank and replacing the pads normally fixes it.

Why are some rooms cool and others not?

Uneven cooling is usually a duct problem: a run that has come loose, is crushed or is too long. A duct check finds where the air is being lost.

TESTIMONIALS

What Our Evaporative Cooling Customers Say About Us

The Process

3 Step Process For Your Evaporative Cooling Needs

Contact Us

Start by completing the 'Get a Free Quote' form on our website to share your Evaporative Cooling needs with us.

Schedule Your Estimate

Next, we'll arrange a property visit at a time that works for you to provide an in-person estimate for your Evaporative Cooling needs.

Get The Job Done

After you approve our estimate, we'll schedule a date to complete the job. Our team will work hard to exceed your expectations!

Request A Free Evaporative Cooling Quote

GET A FREE QUOTE